CIP RC/PT Girder Help

Minimum P-Jack Report

This report shows the minimum P-jack required at each POI to satisfy the final tensile stress condition. This report also shows the jacking force required for top and bottom of the section in separate column.

The POI and Location columns show the name and location of the POI. The Tendon column shows the name of the tendon for which the jacking force is calculated. The Top and Bottom columns show the jacking force required for top and bottom stress. If the stress at the location without consideration of PT is compressive, then P-jack is reported as N/A. Also, if the POI is outside the range of the tendon, then the P-jack is reported as N/A.